S
C
M
YSTEM
ONFIGURATION AND
-
-
CONTINUOUS
REBOOT
PREVENTION
Examples
To enable continuous reboot prevention, use the commands:
awplus#
awplus(config)#
To set the period to 500 and action to stopreboot, use the commands:
awplus#
awplus(config)#
stopreboot
To return the period and action to the defaults and keep the continuous reboot
prevention feature enabled, use the commands:
awplus#
awplus(config)#
To disable continuous reboot prevention, use the commands:
awplus#
awplus(config)#
Related
show continuous-reboot-prevention
commands
show reboot history
show tech-support
C613-50631-01 Rev A
C
ONITORING
OMMANDS
configure terminal
continuous-reboot-prevention enable
configure terminal
continuous-reboot-prevention period 500 action
configure terminal
no continuous-reboot-prevention period action
configure terminal
no continuous-reboot-prevention enable