AS Ser ies Pro gra mm in g M anu al
API
Instruction code
1704
Device
X
S
1
S
2
D
n
Data
type
S
1
S
2
D
n
Symbol
_6
Explanation
1.
The eight external outputs starting from the output specified by D are connected to a four-digit seven-segment
display; or the twelve external outputs starting from the output specified by D are connected to two four-digit seven-
segment displays. Every place is equipped with a driver that converts a binary-coded decimal value into seven-
segment data, and every driver is equipped with a latch that can be used to store state information.
2.
The value in S
second seven-segment display.
3.
S
is for system use only. Please do not alter the value in it.
2
4.
The operand n must be between 0–7. Please refer to the Additional remark for more information.
5.
Whether there is one four-digit seven-segment display or two four-digit seven-segment displays, and whether an
output is a positive logic output or a negative logic output depends on n.
6.
If there is one four-digit seven-segment display, eight outputs are occupied. If there are two four-digit seven-
segment displays, twelve outputs are occupied.
6 - 6 2 6
SEGL
Y
M
S
T
C
is the value to show on first seven-segment display, and the value in S
1
Operand
S
, S
, D, n
1
2
HC
D
FR
SM
Pulse instruction
16-bit instruction
-
: Source device
S
1
: For system use only
S
2
D : First output device
n : Positive/Negative logic
Function
Seven-segment display with latches
SR
E
K
16#
"$"
32-bit instruction
AS
+1 is the value to show on
1
F
-