8.
The instruction is a pulse instruction. Even if the A contact is adopted as the condition contact, PU module
parameters are also set only when the instruction is started. Therefore, if a parameter value is to be updated,
restart the instruction to make the parameter set again.
9.
Since the set parameters are delivered through the module communication command, confirm the state of the
output Done or Error before a parameter value is modified and then proceed with relevant operations.
10.
ErrCode shows error codes. See the description as follows.
Error code
16#1400
16#1401
16#1402
Programming Example: Refer to the description of DPUDRI instruction (API 1405) for more information.
The module does not support the function.
The data stored in the module is illegal or exceeds the allowed range.
There is no response from the module; communication timeout occurs.
Cha p ter 6 App l ied Ins truc tio ns
Description
6_