Delta AS Series Programming Manual page 1084

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Example 1 (S
= 1)
3
1.
This example illustrates how to establish a TCP connection between a computer as server and an AS Series PLC
as client.
ISPSoft → HWCONFIG (Ethernet-Basic)
2.
IP Address Mode
IP Address
Netmask Address
Gateway Address
a) ISPSoft → HWCONFIG (Ethernet-Advanced → Socket → 1
3.
b) SCONF instruction
Remote IP
Remote Port
Local Port
Send Data Address
The defined length of data to be sent
Receive Data Address
The defined length of data to be received
Keep Alive Timer
#1
: This data length is defined by settings in SCONF instruction; for V1.06.20 or previous versions: 512 bytes are
available and for V1.06.30 or later versions: 4096 bytes are available.
4.
First, set the parameters related to TCP Socket1 in HWCONFIG in ISPSoft or in the SCONF instruction.
Ethernet Configuration
Static
192.168.1.111
255.255.255.0
192.168.1.1
st
1
TCP Socket Connection
192.168.1.110
3201
3200
D1000
#1
200
D2000
#1
200
10
Ch ap te r 6 Ap pl ie d Instruc ti ons
st
TCP Socket Connection)
6_
6
6 - 8 0 5