Example 3
The states of the devices are listed below.
State of the contact
Device
before the execution
of CJ M0=OFF
M1, M2, and M3 are
OFF.
Y, M, and S
M1, M2, and M3
are ON.
M4 is OFF.
Timer
M4 is ON.
M6 is OFF.
Accumulative
timer
M6 is ON.
M7 and M10 are
OFF.
Counter
M7 is OFF. M10 is
ON/OFF.
M11 is OFF.
Applied
instruction
M11 is ON.
*1:Y0.1 is a dual output. When M0 is OFF, Y0.1 is controlled by M1. When M0 is ON, Y0.1 is controlled by M12.
State of the contact during the
execution of CJ
M0=ON
M1, M2, and M3 switch from OFF
to ON.
M1, M2, and M3 switch from ON
to OFF.
M4 switches from OFF to ON.
M4 switches from ON to OFF
M6 switches from OFF to ON.
M6 switches from ON to OFF.
M10 is ON/OFF.
M10 is ON/OFF.
M11 switches from OFF to ON
M11 switches from ON to OFF
Ch a pt er 6 Ap p l i ed I ns t r uc t i ons
State of the output coil during the
execution of CJ
M0=ON
*1
Y0.1
, M20, and S1 are OFF.
*1
Y0.1
, M20, and S1 are ON.
The timer is not enabled.
The timer keeps counting and when
the timer setting value is reached, it
drives the output T-coil.
ST1 is not enabled.
The accumulative timer keeps
counting and when the timer setting
value is reached, it drives the output
T-coil.
The counter is not enabled.
C0 stops counting. When M0 switches
OFF, C0 keeps counting.
The applied instruction is not
executed.
The applied instruction is skipped (not
executed).
6_
6 - 1 5 3