AS Ser ies Pro gra mm in g M anu al
Error code
16#1400
16#1401
16#1402
16#1403
16#1404
16#1405
16#1406
16#1407
Programming Example
1.
Set the output point of AS02PU to be "Pulse Y0.0+ direction Y0.1" in HWCONFIG. All parameters of axis 1 are set
as default.
When M0=ON, execute DPUPLS on axis 1, outputting 20,000 pulses from Y0.0 at a frequency of 2kHz (without
2.
acceleration and deceleration). When Y0.1=OFF, the direction is positive.
3.
After Output pulses completed, M1 changes to ON.
_6
6-442
The module does not support the function.
The value stored in the module is illegal or exceeds the allowed range.
There is no response from the module; communication timeout occurs.
There is no such output axis number in the PU module.
The output frequency of the PU module is illegal.
The output axis specified by the PU module is outputting data. It is not allowed to specify the
output repeatedly.
PU module stops Output pulse when the positive limit is reached.
PU module stops Output pulse when the negative limit is reached.