AS Ser ies Pro gra mm in g M anu al
Function option
_6
Reserved
S: The data source
S
: The length of the data that the instruction writes into the file
1
If the value in S
Length of the data
6 - 8 4 6
Item
Code
The unit of the value is a double word.
The file name extension is .txt.
Use ASCII codes.
The value that is stored is a hexadecimal format.
The values are separated by a comma. (V1.04.00 or later supports )
The unit of the value is a Word.
The file name extension is.csv.
7
Use ASCII codes.
The value that is stored is a decimal format.
Appending
The data that is written into the memory card is appended after the last
value in the file.
0
This is the default value
If the file does not exist, it is created automatically.
Overwriting
The data that is written into the memory card replaces the values in the file
1
starting from the value indicated by the value in S
If the file does not exist, it is created automatically.
The values of bit 8–bit 15 are 0.
-
is 0, the instruction does not write any data into the file.
1
Item
If the file format is 0, 1, 3, 5, or 7, the unit of the value is a word. If the file format
Value unit
is 2, 4, or 6, the unit of the value is a double word.
Parameter unit
Double word
The devices where the instruction stores the data cannot exceed the device
range, and the size of the data that the instruction writes into the file cannot be
more than four gigabytes. Refer to Chapter 2 for more information about devices.
Description
.
4
Description