Case 1: when the mark alignment occurs in the ramp-down section
Green line: signal of mark aligment
Blue line: the actual output speed
The operation of the mark alignment (green line: OFF -> ON) begins when the number of pulses is 95,000.
Set S
= 15,000; the output stops after 15,000 pulses at the current speed.
6
Case 2: when the mark alignment occurs in the ramp-down section
Green line: signal of mark aligment
Blue line: the actual output speed
_6
The operation of the mark alignment (green line: OFF -> ON) begins when the number of pulses is 95,000. After the
mark alignment, set S
6 - 9 3 4
to -1, the output stops immediately.
6
15,000 pulse