5.
The connection to remote Client (IP = 192.168.1.106) is connected and sending 2K bytes of data.
6.
Open the Monitor Table and start monitoring the starting device where the data length of the received data is
stored.
If 2K bytes of data is received, you can see the value in D15000 is 2000. If you need to start another data
transmission, you can set the value in D15000 to 0 to start another data length count.
7.
Closing a connection (Network 5): When M3 is ON, the system checks if the socket has been connected. If the
socket has been connected (SM1270 = ON), the system is going to close the connection. If the socket has not
been connected, the system does not execute the instruction. After the connection is closed, M3 is switched to
OFF.