Action
0
No action
1
OFF
2
ON
3
Toggle between ON /OFF
4
OFF + clear the counter value of its channel
5
ON + clear the counter value of its channel
Toggle between ON /OFF + clear the counter value
6
of its channel
Clear the counter value of its channel
7
Clear the counter value of its channel + OFF
8
(appointed all output points by both YnoS)
Note: there is a time difference between meeting the set value and for the action to take place. Up to 100 us of time
difference can be expected.
13. The value in YnoS should be a 16-bit integer and takes several space of Word in CmpLen consecutively.
14. The value in InoS is the interrupt numbers. You can send specific interrupts to the PLC CPU. The allowable interrupt
is ranging from I400 to I431. The value in InoS should be a 16-bit integer and would take several space of Word in
CmpLen consecutively.
InoS
0
No interrupt
 = 00~31; corresponding to I400~I431
4
(When the set value is met, the specific interrupt is requested by a PLC CPU.)
Note: The frequency of the interrupt device I with the same numbering should not be higher than 800Hz.
15. CurNo is the current group number. See the table below for reference. If the counter value is 200, the counted number
is less than the value in D100, and the matched CurNo is 0. If the counter value is 1000, check the table below to find
the value in D100 is also 1000 and the matched CurNo is 1.
Description
YnoS
Appointed output points
0
Y0.0
1
Y0.1
2
Y0.2
3
Y0.3
Action
Cha p ter 6 App l ied Ins truc tio ns
Remarks
When the counter value is cleared, the value
in CurNo is also cleared to zero.
6_
6-515