API
Instruction
2212
EMCONF2
Device
X
Y
M
Index
Mail
Data
type
Symbol
Explanation
1.
This instruciton is available for PLC with FW V1.06.00.
2.
See the operand name, use explanation and data type in the following table.
Operand
Name
Mail address
Index
number
Mail
Mail address
Operand
P
Index,Mail
S
T
C
HC
Refer to following instruction explanation
Pulse Instruction
AS
Index, Mail
Explanation
Index: The mail address number to be
modified (Range: 0~4, 0: Not modify the
mail address.)
Mail +0: the data length of Index value with
the unit of bytes (range: 0~63, 0: Not modify
the mail address.)
Mail +1~ Mail +32: The data content of
Index (Data are placed from the lower 8
bits.)
For example: ex@deltaww.com
D0 = 16#000E, D1 = 16#7865,
D2 = 16#6440, D3 = 16#6C65,
D4 = 16#6174, D5 = 16#7777,
D6 = 16#632E, D7 = 16#6D6F
Up to 63 words can be used in one string
Ch ap te r 6 Ap pl ie d Instruc ti ons
Setting email address
D
FR
SM
SR
16-bit instruction
AS
: Refer to following explanation
Data type
WORD[N]
Description
E
K
16#
"$"
F
32-bit instruction
-
Remark
WORD
Refer to Mail +0
for address
occupation.
33 consecutive
words at most
can be occupied.
String