5.
D only allows Y0.0–Y0.11 as the output devices. After the instruction is executed, its output function becomes the
high-speed output, and the basic instruction output point control is invalid. It is suggested that you do not use the
general output function after using the high-speed output function in the program.
6.
The ratio of Duty-OFF Time and Duty-ON Time for the pulse output is 1:1.
7.
There is no limit to how many times you can use the instruction a program. But only one output instruction that uses
the same output point can be executed in the same scan cycle. When several high-speed pulse output instructions
start the same output point in the program, the PLC first performs the output based on the instruction that is executed
first.
8.
After every high-speed output instruction for every output point is executed, other instruction occupying the same
output point can not start until the high-speed output instruction in execution is disabled.
9.
When the high-speed output instruction is executed in an interrupt program or is not in the main process, it is
suggested that you use the instruction with the auto-reset function when output is completed and the PLC updates
the output state in the END instruction.
10.
After the stop flag is set, the PLC stops the output and clears the busy flag only after executing the start instruction a
second time and outputting a full pulse. The PLC continues to output pulses when the stop flag is reset and the
previously stopped pulse output is not finished. You set and reset the stop flag is set in the program.
11.
The high-speed output points and corresponding SM/SR are listed in the following table.
_6
Output point number
Busy flag
Completion flag
Stop flag
Output completion
auto-reset
Present output
position
(32-bit)
Output point number
Busy flag
Completion flag
Stop flag
6 - 8 8 0
#2
Attribute
Y0.0
R
SM460
#3
R/W
SM461
R/W
SM463
R/W
SM470
#4
SR460
#1
R/W
SR461
#2
Attribute
Y0.6
R
SM520
#3
R/W
SM521
R/W
SM523
Y0.1
Y0.2
Y0.3
SM472
SM480
SM492
SM473
SM481
SM493
SM474
SM483
SM494
SM475
SM490
SM495
SR474
SR480
SR494
SR475
SR481
SR495
Y0.7
Y0.8
Y0.9
SM532
SM540
SM552
SM533
SM541
SM553
SM534
SM543
SM554
Y0.4
Y0.5
SM500
SM512
SM501
SM513
SM503
SM514
SM510
SM515
SR500
SR514
SR501
SR515
Y0.10
Y0.11
SM560
SM572
SM561
SM573
SM563
SM574

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents