A S S er i es Pr og r am m ing M an u a l
After the instruction is executed, the data in the operand D is as follows.
Device
D0
D1
D2
D3
D4
Example 4
When the data in S is not a string and the ending code 16#00 appears in the high byte, the execution of the instruction is
as follows.
The operand S:
Device
_6
D100
D101
D102
D103
After the instruction is executed, the data in the operand D is as follows.
Device
D0
D1
D2
D3
6 - 1 2 8
High byte
Low byte
16#31
16#30
16#33
16#32
16#35
16#34
16#00
16#00
Unchanged
Unchanged
High byte
Low byte
16#31
16#30
16#33
16#32
16#00
16#34
16#37
16#36
High byte
Low byte
16#31
16#30
16#33
16#32
16#00
16#34
Unchanged
Unchanged
Note
'1'=16#31; '0'=16#30
'3'=16#33; '2'=16#32
'5'=16#35; '4'=16#34
The ending code 16#00 is in the low byte.
16#00 is automatically added in the high byte.
Note
'1'=16#31; '0'=16#30
'3'=16#33; '2'=16#32
16#00 is the ending code. '4'=16#34
'7'=16#37; '6'=16#36
Note
'1'=16#31; '0'=16#30
'3'=16#33; '2'=16#32
16#00 is the ending code. '4'=16#34