Case 2: when the mark alignment occurs in the ramp-up section
Green line: signal of mark aligment
Blue line: the actual output speed
The operation of the mark alignment (green line: OFF -> ON) begins when the number of pulses is 6000. The target
frequency of 10 kHz can be reached if S
15,000 pulse
When the mark alignment occurs in the target frequency section
Green line: signal of mark aligment
Blue line: the actual output speed
The operation of the mark alignment (green line: OFF -> ON) begins when the number of pulses is 50,000. Set S
15,000; the output stops after 15,000 pulses.
is 15,000.
6
15,000 pulse
Cha p ter 6 App l ied Ins truc tio ns
6_
=
6
6 - 9 3 3