Delta AS Series Programming Manual page 1160

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Output point number
Output completion
#4
auto-reset
Present output position
#1
(32-bit)
Notes:
#1: All present output positions are latched when power is off.
#2: R means Read-only registers, and the data in the registers cannot be modified. R/W means the data in the
registers can be read and written.
#3: It is suggested that you clear the completion flag. If the completion flag is not cleared, it is cleared automatically
when the high-speed output instruction is executed the next time.
#4: You set the output completion auto-reset flag. The PLC clears the flag automatically after the output is
completed.
Example 1
1.
When X0.0 is ON, Y0.0 outputs 200 pulses at 1kHz. SM461 is ON when the pulse output is completed and then
Y0.12 is ON.
2.
When X0.0 is OFF, Y0.0 stops the output. It restarts the pulse output when X0.0 switches to ON again.
輸出 Y0
Output point Y0.0
#2
Attribute
Y0.0
Y0.1
R/W
SM530
SM535
SR520
SR534
R/W
SR521
SR535
0.5ms
2
1ms
Cha p ter 6 App l ied Ins truc tio ns
Y0.2
Y0.3
SM550
SM555
SR540
SR554
SR541
SR555
3
200
Y0.4
Y0.5
SM570
SM575
SR560
SR574
SR561
SR575
6 - 8 8 1
6_