Delta AS Series Programming Manual page 1355

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

A S S e r i e s P r o g r a m m i n g M a n u a l
The device which receives the data in
6206
the TCP socket function is illegal.
The data received through the TCP
6208
socket exceeds the device range.
The remote communication IP address
6209
set in the UDP socket function is illegal.
The local communication port set in the
620A
UDP socket function is illegal.
The device from which the data is sent
620C
in the UDP socket function is illegal.
The device which receives the data in
620F
the UDP socket function is illegal.
_7
The data received through the UDP
6210
socket exceeds the device range.
There is no response from the remote
6212
device after the timeout period.
6213
The data received exceeds the limit.
The remote device refuses the
6214
connection.
6215
The socket is not opened.
7 - 1 4
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > TCP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > TCP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > UDP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > UDP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > UDP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > UDP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > UDP
Socket.
Make sure that the remote device is connected.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > UDP
Socket.
Make sure the remote device operates normally.
Check if operational sequence in the program is
-
X
-
X
-
X
-
X
-
X
-
X
-
X
-
X
-
X
-
X
-
X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents