AS Ser ies Pro gra mm in g M anu al
14.
The error codes that ErrCode shows are listed in the following table.
Error code
16#1410
16#1411
16#1414
Example
After calibration is done, you can use DLCWEI instruction to weigh.
1.
Weighing: Leave a weight of 500 g on the weighing platform. When M1 switches to ON, the value in D204 shows
500.0.
2.
Set up the tare weight
  Leave a packaging (100 g) on the weighing platform. The value in D204 shows 100.0.
  When M151 switches to ON, Weight value (D204) is moved to TareW value (D202). After moving, clear the
weight value in D204.
  D204 = 0.0 and D202 = 100.0. The setup of tare weight is complete.
3.
Clear the tare weight
  When M151 switches to OFF, the TareW value (D202) is moved back to Weight value (D204). After moving,
clear the TareW value in D202.
_6
  D202 = 0.0 and D204 = 100.0. The setup of clearing the tare weight is complete.
4.
Specify a stable-weight range (checking the stability)
  Before executing this instruction, you need to specify the stable-weight range. Here we set D200 = 10.0.
  Leave a 500 g weight on the weighing platform. When the measurement result is between 490 ~ 510 g,
D210 =1 (the weight is stable).
6-472
Error in the LC group number or module number
The LC module has no such channel number
Error in data-writing or communication timeout on LC module
Description