API
2708
Device
X
S
1
S
2
S
3
S
4
S
5
D
1
D
2
Data
type
S
1
S
2
S
3
S
4
S
5
D
1
D
2
_6
Symbol
Explanation
1.
This instruction specifies the catch speed and proportional output. S
and X0.10 as the input points, and the operand occupies two consecutive input points. You cannot execute the
instruction if the input points are the points specified for S
counter is automatically specified. If there is a DCNT instruction (API 1004) with the same high-speed counter in
6 - 9 2 2
Instruction
CSFO
S
1
Y
M
S
T
S
1
S
2
S
3
S
4
S
5
D
1
D
2
Operand
,S
,S
,S
,S
,D
,D
2
3
4
5
1
2
C
HC
D
FR
SM
Pulse Instruction
16-bit instruction
Signal input device
Number of input pulses
Pulse input frequency
Denominator (output frequency) for the proportion of the input
frequency and output frequency
Numerator (input frequency) for the proportion of the input
frequency and output frequency
Pulse output device
Pulse output frequency
1
above. After you select the input points, the high-speed
1
Description
Catch speed and proportional output
SR
E
K
16#
32-bit instruction
AS
can only specify X0.0, X0.2, X0.4, X0.6, X0.8
"$"