AS Ser ies Pro gra mm in g M anu al
Example
1.
When X0.1 is ON, Y0.0 is ON. The instruction performs the logical operation AND on each pair of corresponding bits
in C0 and C10. When the operation result is not 0, Y0.0 is ON.
2.
When X0.2 and X0.3 are ON, Y0.1 is ON. The instruction performs the logical operation OR on each pair of
corresponding bits in the 32-bit register (D10, D11) and the 32-bit register (D20, D21). When the operation result is
not 0, Y0.1 is ON. The instruction performs the logical exclusive operation OR on each pair of corresponding bits in
the 32-bit counter HC0. and the 32-bit register (D200, D201). When the operation result is not 0, Y0.1 is ON.
_6
Additional remarks
If the value in S
or S
1
16#2003.
6 - 2 5 4
is not valid, the condition of the instruction is not met, SM0 is ON, and the error in SR0 is