Delta AS Series Programming Manual page 780

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

API
Instruction
1420
HCDO
Device
X
Y
M
Module
Update
DOdata
DOstat
Error
ErrCode
Data type
Module
Update
DOdata
DOstat
Error
ErrCode
Symbol
Explanation
1.
This instruction is for AS02HC-A only. You can start, stop the counter as well as set up and edit the counter value.
This instruction is available for PLC with FW V1.08.or later and ISPSoft V3.10 or later.
2.
Before executing this instruction, you need to set up DOdata. Once En is activated, the PLC scans the values in
DOdata immediately. DOdata is the initial status of the output points Y0.0 ~ Y0.3. If you need to change the status of
the output point, you need to set new values in DOdata and set the Update to ON. Once the values in DOdata is
updated, the Update switches to OFF.
3.
Module: The module number that is connected to the right side of PLC directly or connected to the remote module
that acts as PLC, e.g. the first connected module is module number 1, the second connected module is module number
2. Up to 32 modules can be connected and counted and each type of modules should be included in the count.
Operand
Module ~ ErrCode
S
T
C
HC
D
Pulse Instruction
Module : Module number
Update : Channel number
DOdata : Digital output data
DOstat : Digital output state
Error
ErrCode : Error code
Cha p ter 6 App l ied Ins truc tio ns
HC module digital output point
FR
SM
SR
E
16-bit instruction
AS
: Error flag
Description
K
16#
"$"
F
32-bit instruction
6-501
6_

Hide quick links:

Advertisement

Table of Contents
loading