AS Ser ies Pro gra mm in g M anu al
API
Instruction code
1206
Device
X
D
1
D
2
Data
type
D
1
D
2
Symbol
Explanation
1.
This instruction clears the values in D
_6
2.
When the device number of D
3.
The ZRST instruction can use the 32-bit counter.
Example
1.
When X0.0 is ON, the instruction resets the auxiliary relays M300–M399 to OFF.
2.
When X1.0 is ON, the instruction resets the 16-bit counters C0–C127. The values of C0–C127 are cleared to zero,
and the contact and the coil are reset to OFF.
3.
When X2.0 is ON, the instruction resets the stepping relays S0–S127 to OFF.
4.
When X3.0 is ON, the instruction resets the output relays Y0.0–Y1.15 to OFF.
5.
When X4.0 is ON, the instruction resets the 32-bit counters HC0–HC63. The values of HC0–HC63 are cleared to
zero, and the contact and the coil are reset to OFF.
6.
When X5.0 is ON, the instruction resets the timers T0–T127. The values of T0–T127 are cleared to 0. and the
contact and the coil are reset to OFF.
6 - 3 7 0
ZRST
P
Y
M
S
T
C
–D
1
is larger than the device number of D
1
Operand
D
, D
1
2
HC
D
FR
SM
Pulse instruction
AS
: First device to be reset
D
1
: Last device to be reset
D
2
. The device type for D
–D
2
1
2
, the instruction resets only D
2
Function
Resetting a zone
SR
E
K
16#
16-bit instruction
32-bit instruction
AS
should be the same for this instruction.
"$"
F
-
.
2