Starting device where received
data are stored
Communication completion
flag
Communication error flag
1.
As M1 is on, set the MsgID of the sent message to 1 and MsgID of the received message to 2. Then the data
sending begins.
A.
Sending the data in D10~D15 (6 bytes) to the slave is performed.
Device
Content
B. The received response data from the slave are stored in D100~D109. M100 changes to On as the receiving is
done.
Device
Content
2.
Master programming example
D100 for storing MsgID,
D101 for storing the number of received packets
D102.... for storing received data
M100
M101
D10~D15
H0A (Defined by users)
D100
2
Cha p ter 6 App l ied Ins truc tio ns
D101
D102~D109
8
H0B
6_