12-2 Advanced troubleshooting procedures
5 List the peripheral module (PM) loads at the input-output (IO) device
6 Load the RLCM with the LOADPM command.
7 Test the RLCM.
8 Return to service the RLCM.
9 The procedure is complete.

Powering down the RLCM

Power down the RLCM from the MAP terminal with the following steps:
1 Post the RLCM.
2 Identify the unit to power down.
3 To busy the RLCM unit, type
297–8351–550 Standard 04.01 August 1999
that you want to use to RTS the units. To perform the following action if
this action was not performed during the power-up procedure, type
>DSKUT;LISTVOL volume name ALL
and press the Enter key.
or, if you load from a DMS Supernode, type
>DISKUT;LV CM;LF volume name
and press the Enter key.
where
volume name is the volume where the PM loads are found
Note: List the PM loads one time only.
CAUTION
Loss of service
Reserve this procedure for extreme conditions, like when
a natural disaster is about to occur. This action results in a
loss of subscriber service.
>BSY UNIT unit_no
and press the Enter key.
where
unit_no is the number of the unit to power down.