3-24 ESA maintenance overview
RLCM ESA tones
Tone type
Busy
Reorder
ROH*
Audible
Warble
Dial
Note:
receive path to a port that provides idle tone.
Providing tones
The following steps provide tone to a subscriber:
1 The ESA processor sends a start-cadence message to the ESA clock and
2 On receipt of the start cadence message, the ESA clock and tone card
The following steps clear the tone:
1 The ESA processor sends a stop-cadence message to the ESA clock and
2 On receipt of the stop cadence message, the ESA clock and tone card
297–8351–550 Standard 04.01 August 1999
Tone ID
(HEX)
81
82
83
80
8D
06
Idle tone uses a start-cadence message, but the RLCM connects the
tone card. This message specifies the tone required, the terminal
identification and the cadence times.
perform the following:
a. If necessary, the current receive path connection of the terminal is
broken.
b. The receive path of the terminal connects to the appropriate port.
c. The specified cadence for that tone is set up.
tone card. This message specifies the terminal identification.
send stop-cadence messages to the LCM. The LCM must disconnect the
terminal connection to the correct port and channel 16.
Channel appearance
Port
Channel
1
16
1
16
2
16
4
16
5
16
7
16
Cadence (in seconds)
On
Off
0.5
0.5
0.25
0.25
0.1
0.1
2.0
4.0
2.0
4.0
N/A
N/A