Nortel DMS-100 Series Maintenance Manual page 289

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

21
CAUTION
Failure to allow enough time can cause false alarm
indication.
Allow 3 to 5 min for the system to clear the alarm
before you proceed to the next step.
Determine if the problem is a drawer that has defects. Letters that appear
under the line subgroup numbers indicate a drawer that has defects. The line
subgroup numbers associate with a physical drawer.
Example of a MAP response:
LCM
REM1 00 0
Unit0: InSv
Unit1: InSv
Drwr:
01 23 45 67 89 01 23 45 67 89
.. SS .. .. .. .. .. .. .. ..
If the system
indicates the problem is a drawer
with defects
indicates the system is not a
drawer with defects
RLCM alarm clearing procedures 7-105
ISTb
Links OOS: Cside
11 11 11 11 11 RG: Pref 0 InSv
DMS-100 Family RLCM Maintenance Manual XPM12 and up
minor
0 Pside
/RG: 0
/RG: 0
Stby 1 InSv
Do
step 22
step 25
RLCM
(continued)
0