Nortel DMS-100 Series Maintenance Manual page 176

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-6 Recovery procedures
RLCM recovery procedure
RLCM recovery procedure
At the MAP terminal
1
2
3
4
5
Link 1: LTC 0
297–8351–550 Standard 04.01 August 1999
(continued)
To silence an alarm that is still audible, type
>MAPCI;MTC;SIL
and press the Enter key.
To access the PM level of the MAP display, type
>PM
and press the Enter key.
To identify the defective RLCM, type
>DISP STATE CBSY LCM
and press the Enter key.
If response
shows CBsy LCMs are not present
shows CBsy LCMs
To post the RLCM with the alarm condition, type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCM (0–511)
lcm
is the number of the LCM (0 or 1)
To identify central -side (C-side) links to the host peripheral module (PM), type
>TRNSL C
and press the Enter key.
Example of a MAP response:
0
2; Cap MS; Status: SysB
6; Cap MS; Status: SysB
Do
step 11
step 4
;MsgCond: CLS
;MsgCond: CLS