8-14 Card replacement procedures
NT0X91
RLCE
(continued)
45
46
47
At the MAP display
48
49
297–8351–550 Standard 04.01 August 1999
Press the RESET button on the NT2X09 power converter while setting CB5, on
the FSP to the ON position. Both the converter FAIL LED and FRAME FAIL
lamp on the FSP will go off.
Remove the wrist strap.
Determine if a Converter Fail LED is lit.
If Converter Fail LED is
lit
not lit
Post the LCM that is controlled by the alarm and control card you have just
replaced by typing
>POST LCM site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site where the LCM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM unit with the new FSP card
Load the LCM unit by typing
>LOADPM UNIT 0 CC
and pressing the Enter key.
If
message loadfile not found
in directory is not received
load passed
load failed
Do
step 80
step 48
Do
step 50
step 71
step 80