Nortel DMS-100 Series Maintenance Manual page 333

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

50
Query the LCM for the name of the current PM load by typing
>QUERYPM
and pressing the Enter key.
Example of a MAP response:
M Type: LCM
Int. No.: 11
P
Memory Size – Unit 0: 256K , Unit 1: 256K
Loadnames:LCMINV –XLCM08AX, Unit0:XLCM08AX, Unit1:XLCM08AX
LCM REM1 00 0 is included in the list of LCM types
scheduled for a REX test.
Last REX test was WED. 1995/04/19 at 02:09:33; PASSED.
Node Status: {OK, FALSE}
Unit 0 Status:{OK, FALSE}
Unit 1 Status:{OK, FALSE}
Site Flr RPos
REM1
01
A02
Services : NEUTRAL
Note: Dashed boxes indicate a valid loadname.
51
Determine the type of device where the PM load files are located.
If load files are located on
tape
IOC disk
SLM disk
52
Locate the tape that contains the PM load files.
At the IOE frame
53
Mount the tape on a magnetic tape drive.
At the MAP display
54
Download the tape by typing
>MOUNT tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
Status index: 6
Bay_id
Shf
Description
RLCE 00
04
LCM
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-15
RLCE
Node_No: 111
Slot
14 0
Do
step 52
step 58
step 63
NT0X91
(continued)
EqPEC
6X04AA

Advertisement

Table of Contents
loading