Nortel DMS-100 Series Maintenance Manual page 364

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-46 Card replacement procedures
NT2X48
RMM
(continued)
Replacing an NT2X48 card in an RMM
At your current location
1
At the MAP display
2
3
297–8351–550 Standard 04.01 August 1999
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the TTP level of the MAP and post the ESA digitone receivers
associated with the card to be replaced by typing
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
ckt_no
is the number of the first circuit where the NT2X48 card is physically
located.
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
3
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
RMM
0 0
Busy and installation busy the trunks that are associated with the card to be
replaced by typing
>BSY;BSY INB;NEXT
and pressing the Enter key.
Note: Repeat this step for each circuit associated with the NT2X48 being
replaced.
1125
BUSY Q
COM LANG
ESAGDTR 11
DIG
STA S R DOT TE R
CFL