Nortel DMS-100 Series Maintenance Manual page 181

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

19
To post the host XPM links and check link conditions for slips and framing
errors, type
>POST pm pm_no link_no
and press the Enter key.
where
pm
is a line group controller (LGC), line trunk controller (LTC), or
remote cluster controller (RCC)
pm_no
is the number of the peripheral (0 to 127)
link_no
is the number of the link associated with the host XPM
(refer to step 17 display)
Repeat the POST command for each link.
Example of a MAP response:
Host XPM P-side link number
N CLASS SITE LTC CK D ALRM SLIP FRME BER ES SES STATE
0 REMOTE HOST
Note: The display shows carrier facilities from the host XMS-based PM (XPM)
to the RLCM. You must check the carrier facilities from the remote site back to
the host XPM.
If link conditions
show a high number of SLIP and
FRME
show a very low number of SLIP
and FRME
20
To post the RLCM with the alarm condition, type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCM (0–511)
lcm
is the number of the LCM (0 or 1)
RLCM recovery procedure
1
0
C
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Recovery procedures 6-11
0
0
1
0
Do
Leave the RLCM in ESA. Go to
step 27.
step 20
(continued)
0
INSV

Advertisement

Table of Contents
loading