Nortel DMS-100 Series Maintenance Manual page 448

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-130 Card replacement procedures
NT6X47
HIE
(continued)
Replacing an NT6X47 card in an HIE
At your current location
1
2
At the MAP terminal
3
4
At the RLCE frame
5
6
297–8351–550 Standard 04.01 August 1999
Obtain a replacement card. Verify that the replacement card has the same
product engineering code (PEC), including suffix, as the card to be removed.
If you were directed to this procedure from another maintenance procedure, go
to step 5; otherwise, continue with step 3.
Post the ESA processor by typing
>MAPCI;MTC;PM;POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor (0 to 255)
Busy the ESA processor by typing
>BSY
and pressing the Enter key.
Example of a MAP response:
This action will take this PM out of service
Please confirm ("Yes" or "No")
Respond by typing
>YES
and pressing the Enter key.
Replace the NT6X47 card using the procedure "Replacing a card". When you
have completed the procedure, return to this point.
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 7.