7-58 RLCM alarm clearing procedures
RLCM RG
major
(continued)
At the MAP terminal
7
8
9
297–8351–550 Standard 04.01 August 1999
Ensured both LCM units are aligned to the good RG by typing
>SWRG UNIT unit_no
and pressing the Enter key.
where
unit_no
is the LCM unit (0 or 1) associated with the faulty RG
Example of a MAP display:
LCM REM1 14 1 Unit 1 SWRG Passed
Note: Repeat this step until both units of the LCM are on the good RG.
If the SWRG command
passed
failed
Manually busy the ISTb LCM unit identified in step 2 by typing
>BSY UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the ISTb LCM unit.
Test the ManB LCM by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the ManB LCM unit.
If cardlist is
generated
not generated
Do
step 8
step 18
Do
step 10
step 18