Nortel DMS-100 Series Maintenance Manual page 467

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

23
List the SLM file names into your user directory by typing
>LV CM;LF volume_name
and pressing the Enter key.
where
volume_name is the name of the volume that contains the PM load files,
obtained in step 21.
24
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
25
Load the LCM unit by typing
>LOADPM UNIT lcm_unit CC
and pressing the Enter key.
where
lcm_unit
is the LCM unit to be loaded (0 or 1)
If
load failed
load passed
26
Return the LCM unit to service by typing
>RTS UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the LCM busied in step 5 (0 or 1)
If RTS
passed
failed
27
Send any faulty cards for repair according to local procedure.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-149
RLCM
Do
step 29
step 26
Do
step 27
step 29
NT6X51
(continued)

Advertisement

Table of Contents
loading

Table of Contents