Nortel DMS-100 Series Maintenance Manual page 478

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-160 Card replacement procedures
NT6X53
RLCM
(continued)
Replacing an NT6X53 in an RLCM
At your current location
1
2
At the MAP display
3
297–8351–550 Standard 04.01 August 1999
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
Access the PM level of the MAP and post the LCM by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the name of the RLCM site
frame
is the frame number of the RLCE frame (0 to 511)
lcm
is the number of the LCM
Example of a MAP display:
CM
MS
IOD
.
.
.
LCM
SysB
0 Quit
PM
0
2 Post_
LCM
0
3
4 SwRg
LCM
5 Trnsl
Unit–0:
6 Tst
Unit–1:
7 Bsy
8 RTS
Drwr: 01 23 45 67 89 01 23 45 67 89
9 OffL
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
Net
PM
CCS
LNS
.
1LCM
.
.
ManB
OffL
0
0
0
0
Rem1
OO O ISTb
Links_OOS: CSide 0 PSide 0
InSv
Mtce TakeOver
SysB
Mtce
11 11 11 11 11 RG:Pref:0 InSv
.. .. .. .. .. .. .. .. .. ..
Trks
Ext
Appl
.
.
.
CBsy
ISTb
InSv
0
1
130
0
1
10
/RG:
0
/RG:
0
Stby:1 InSv

Advertisement

Table of Contents
loading