Nortel DMS-100 Series Maintenance Manual page 473

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

13
Demount the tape by typing
>DEMOUNT T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
14
Go to step 25.
15
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
16
Access the disk utility level of the MAP by typing
>DSKUT
and pressing the Enter key.
17
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name is the name of the volume that contains the PM load files
obtained in step 15
18
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
19
Go to step 25.
20
From office records, determine and note the number of the system load module
(SLM) disk and the name of the volume that contains the PM load files.
21
Access the disk utility level of the MAP by typing
>DISKUT
and pressing the Enter key.
22
List the SLM disk volume names by typing
>LV CM
and pressing the Enter key.