To power up the converter in the LCM unit of the RLCM, switch ON the circuit
breaker that you turned OFF in step 31.
34
To attempt to load the LCM unit, type
>LOADPM UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit of the RLCM that you are loading (0 or 1)
If load
is successful
fails
35
To test the LCM unit, type
>TST UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit of the RLCM that you are testing (0 or 1)
If test
passes
fails, and the system generates a card list
fails, and the system does not generate a card
list
36
To attempt to return the LCM unit to service, type
>RTS UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit of the RLCM you are returning to service (0 or 1)
If RTS
passes
failes
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-15
critical
Do
step 35
step 30
Do
step 36
step 26
step 30
Do
step 37
step 30
RLCM
(continued)