Perform the correct procedure for the type of frame with the FSP alarm.
Complete the procedure and return to this point.
At the RLCE frame
109
Inspect the FSP. Check circuit breakers CB8 and CB9.
If circuit breakers
are tripped
are not tripped
110
Reset circuit breaker (CB8 or CB9). Move the switch to the ON/OFF position
and immediately back to the ON position. The LED goes OFF.
If circuit breaker
trips again
remains ON (LED turns off)
111
Access the Table of Contents for the RLCM talk battery alarm procedure.
Return to this step when the procedure is complete.
112
For additional help, contact the next level of support.
113
The procedure is complete.
RLCE frame major
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-85
RLCE frame major
Do
step 110
step 113
Do
step 111
step113
Ext FSP
Ext FSP
(continued)
(end)