Nortel DMS-100 Series Maintenance Manual page 349

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6
Go to the PM level of the MAP and post the RMM by typing
>PM;POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
Example of a MAP display:
SysB
PM
0
RMM
0
RMM
0
7
Busy the RMM by typing
>BSY
and pressing the Enter key.
At the RMM shelf
8
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap
grounding point of a frame supervisory panel (FSP)
while handling circuit cards. This protects the cards
against damage caused by static electricity.
Power down the unit by setting the ON/OFF switch on the power converter
faceplate to the OFF position. Both the converter FAIL LED and FRAME FAIL
lamp on the frame supervisory panel (FSP) will be ON. An audible alarm may
sound. If an alarm does sound, silence it at the MAP terminal by typing
>SIL
and pressing the Enter key.
9
Replace the NT2X09 card using the procedure "Replacing a card". When you
have completed the procedure, return to this point.
10
Power up the RMM unit as follows:
a.
Ensure that the converter (NT2X09) is inserted. A major audible alarm may
sound. This alarm is silenced when power is restored to the converter.
b.
Set the POWER switch to the ON position.
ManB
Offl
2
2
0
1
InSv
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-31
RMM
CBsy
ISTb
0
7
0
0
NT2X09
(continued)