7-124 RLCM alarm clearing procedures
RMM
minor
(continued)
9
10
11
12
297–8351–550 Standard 04.01 August 1999
To test the ManB link, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of the link (0 or 1) manually busied in step 8
If
TST PASSED
TST FAILED
To RTS the link, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of the link (0 or 1) tested in step 9
If
RTS PASSED
RTS FAILED
Determine if additional links must be clear.
If all the links that had defects
are clear
are not clear
To post the RMM, type
>POST RMM rmm_no
and press the Enter key.
where
rmm_no
is the number of the RMM to post
Do
step 10
step 16
Do
step 11
step 16
Do
step 12
step 8