Nortel DMS-100 Series Maintenance Manual page 457

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

9
Post the LCM by typing
>POST LCM site frame lcm_no
and pressing the Enter key.
where
site
is the name of the RLCM site (alphanumeric)
frame
is the frame number of the RLCE (0–511)
lcm_no
is the number of the LCM
10
Busy LCM unit 0 for card in slot 19 or LCM unit 1 for card in slot 20 by typing
>BSY UNIT lcm_unit_no
and pressing the Enter key.
where
lcm_unit_no
is the RLCM unit to be busied, (0 or 1).
11
Post the C-side peripheral module, previously posted in step 5, where the
RLCM is connected by typing
>POST host_pm host_pm_no
and pressing the Enter key.
where
host_pm
host_pm_no
12
Using the information collected in steps 6 and 7, busy both links associated with
the faulty card by typing
>BSY LINK link_no
and pressing the Enter key.
where
link_no
is one of two links associated with the faulty card
Note: Repeat this step for the other link associated with the faulty card.
is the name of the host PM, previously posted in step 5
is the number of the host PM (0 to 255)
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-139
HIE
NT6X50
(continued)