6-12 Recovery procedures
RLCM recovery procedure
21
22
23
24
297–8351–550 Standard 04.01 August 1999
(continued)
To busy both units of the RLCM, type
>BSY PM
and press the Enter key.
The system requests verification. to respond, type
>YES
and press the Enter key.
To test both units of the RLCM, type
>TST PM
and press the Enter key.
If test
passes
fails, and the system produces a
card list
fails, but the system did not produce
a card list
The card list identifies the cards that can be defective. Replace the cards one
at a time in the order that this procedure lists.
If last card on list
is not replaced
is replaced
To attempt to return the RLCM to service, type
>RTS PM
and press the Enter key.
If MAP prompt
shows RTS is successful
shows CBsy
shows load failure
shows any other message
Do
step 24
step 23
step 27
Do
step 28
step 27
Do
step 32
step 5
step 25
step 27