Replacing an NT2X70 card in an HIE shelf
At your current location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
2
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC) including suffix, as the card to be removed.
At the MAP display
3
Access the PM level of the MAP display and post the remote line concentrating
module (RLCM) associated with the faulty NT2X70 card by typing
>MAPCI;MTC;PM;POST LCM site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site, where the RLCM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM module in the frame
If the NT2X70 card is in
slot 25
slot 22
4
Display the P-side links of the RLCM by typing
>TRNSL P
and pressing the Enter key.
Example of a MAP display:
Link
0:
RMM 0
Link
1:
RMM 0
Link
2:
ESA 0
Link
3
ESA 0
Note: In this example both the RMM and ESA modules are provisioned.
However, should either of these modules not be provisioned in your
office, skip the steps relating to that module and continue with the rest
of the procedure.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-61
Do
step 4
step 36
0;
Cap MS;Status:
1;
Cap MS;Status:
0
Cap M ;Status:
1
Cap M ;Status:
NT2X70
HIE
(continued)
OK; MsgCond:OPN
OK; MsgCond:OPN
OK; MsgCond:OPN
OK; MsgCond:OPN