Replacing an NT6X21 card in an RLCM
At your current location
1
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
2
Make DIP switch changes for the line card.
If the line card code is
AA, AB, AC
AD
Make DIP switch settings as referenced in the Maintenance section of this
3
manual.
At the MAP terminal
4
Access the LTP level of the MAP terminal and post the line associated with the
card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site lcm lsg ckt
and pressing the Enter key.
where
site
is the name of the site where the RLCM is located
lcm
is the number of the RLCM with the faulty card
lsg
is the number of the line subgroup with the faulty card
ckt
is the number of the circuit associated with the faulty card
Example of a MAP response:
LCC PTY RNG .....LEN.......... DN
1FR
REM1 00 0 03 03
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-105
RLCM
Do
step 4
step 3
STA F S LTA TE RESULT
7213355 MB
NT6X21
(continued)