Nortel DMS-100 Series Maintenance Manual page 547

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP terminal
5
To access the peripheral module (PM) level of the MAP (maintenance and
administration position) display and post the LCM, type
>MAPCI;MTC;PM;POST LCM site frame_no lcm_no
and press the Enter key.
where
site
is the PM location (alphanumeric)
frame_no
is the equipment frame number (00 to 511)
lcm_no
is the number of the LCM (0 or 1)
Example of a MAP display:
LCM
REM1 01 1
Unit0: ISTb
Unit1: ISTb
Mtce
Drwr:
01
23
45
..
..
..
6
Record the numbers of the logical drawers for the NTEX54.
Note: Logical drawers configure in pairs for the physical drawer. The NTEX54
services the physical drawer. Both logical drawers must be manually busy to
perform this card replacement procedure.
7
Check the state of the affected logical drawers.
If the state for
one or both logical drawers is I,S,
or . (dot)
both logical drawers is M
one or both logical drawers is 0 or –
DMS-100 Family RLCM Maintenance Manual XPM12 and up
ISTb
Links OOS: Cside
/RG: 0
/RG: 1
11
11
11
67
89
01
23
45
..
MM
..
..
..
Card replacement procedures 8-229
RLCM
0 Pside
0
Ring gen Test
11
11
RG: Pref 1 InSv
67
89
Stby 0 InSv
..
..
Do
step 8
step 11
Determine why the drawer is offline.
If necessary, contact the next level
of support.
NTEX54
(continued)

Advertisement

Table of Contents
loading

Table of Contents