Nortel DMS-100 Series Maintenance Manual page 350

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-32 Card replacement procedures
NT2X09
RMM
(continued)
11
12
At the MAP display
13
14
15
At the IOE frame
16
297–8351–550 Standard 04.01 August 1999
Press the RESET button on the power converter while setting the circuit
breaker on the frame supervisory panel (FSP) to the ON position. Both the
converter FAIL LED and FRAME FAIL lamp on the FSP will be ON.
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 13.
Go to the PM level and post the RMM, if not already posted, and load the RMM
by typing
>PM;POST RMM rmm_no;LOADPM
and pressing the Enter key.
where
rmm_no
is the number of the RMM associated with the new NT2X09 card
If
message "loadfile not found in
directory" is received
load passed
load failed
Determine the type of device on which the RMM load files are located.
If
tape
IOC disk
SLM disk
Locate the tape that contains the PM load files.
Mount the tape on a magnetic tape drive.
Do
step 14
step 31
step 36
Do
step 15
step 21
step 26

Advertisement

Table of Contents
loading

Table of Contents