Nortel DMS-100 Series Maintenance Manual page 527

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

29
List the disk volume names for both S00D and S01D by typing
>LV CM
and pressing the Enter key.
30
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name is the name of the volume that contains the PM load files,
obtained in step 27.
31
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
32
Reload the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
33
Return the ESA processor to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
34
Send any faulty cards for repair according to local procedure.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-209
HIE
Do
step 36
step 33
Do
step 34
step 36
NT6X75
(continued)