8-242 Card replacement procedures
NTEX54
RLCM
(continued)
At the xEMS workstation
27
28
29
30
31
32
33
34
35
36
37
297–8351–550 Standard 04.01 August 1999
i.
Exit the table. Type
>QUIT
and press the Enter key.
CAUTION
Transport network must know new MAC address
Before you return the DBIC to service, you must
provide the MAC address for the DBIC to the
transport network. Contact the network administrator
for assistance.
Go to the submap of the LCM line drawer with the new NTEX54 card.
Select the card by placing the cursor on the DBIC.
From the pop-up menu select Describe/Modify Object. The Object Description
dialog box appears.
From the Object Description dialog box, select HSTP Application from the fields
under Object Attributes.
Select View/Modify Object Attributes.
Enter the new MAC address in the %LAC MAC Address field, for example,
0060381120a1.
Click the Verify button to verify the information.
Click the OK button to close the Attributes dialog box.
Click OK to close the Object Description dialog box.
Place the cursor on the DBIC you want to return to service and use the mouse
to select
Maintenance –> DBIC –> Rts
from the pop-up menu.
Send any faulty cards for repair according to local procedure.