Nortel DMS-100 Series Maintenance Manual page 449

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP terminal
7
Load the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
message "loadfile not found in
directory" is received
load passed
load failed
8
Determine the type of device on which the PM load files are located.
If load files are located on
tape
IOC disk
SLM disk
9
Locate the tape that contains the PM load files.
At the IOE frame
10
Mount the tape on a magnetic tape drive.
At the MAP terminal
11
Download the tape by typing
>MOUNT tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
12
List the contents of the tape in your user directory by typing
>LIST T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-131
HIE
Do
step 8
step 26
step 29
Do
step 9
step 15
step 20
NT6X47
(continued)

Advertisement

Table of Contents
loading