Nortel DMS-100 Series Maintenance Manual page 227

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Summary of clearing an RLCM major alarm
At PM level of
MAP, display
ISTb LCMs
Post ISTb LCM
Query LCM for
faults
Ringing
generator
fault?
N
CBsy fault?
N
SysB fault?
N
LCM unit is
ManB
Y
Y
Is ringing
generator
LED on?
N
2
Y
3
Y
2
6
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-43
This flowchart summarizes the
procedure.
Use the instructions that follow
this flowchart to perform the
procedure.
Power up
ringing
generator
RLCM
major
(continued)
Y
Is power
1
restored?
N
2