Nortel DMS-100 Series Maintenance Manual page 430

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-112 Card replacement procedures
NT6X27
in HIE
(continued)
9
10
11
12
At the PRLCM cabinet
13
297–8351–550 Standard 04.01 August 1999
To post the ILCM, type:
>POST ILCM site frame lcm_no
and press the Enter key.
where
site
is the name of the PRLCM site (alphanumeric)
frame
is the frame number of the PRLCM cabinet
Icm_no
is the number of the ILCM
To busy the ILCM unit, type:
>BSY UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the ILCM unit to be busied zero or one
Note: For ILCM unit 0, card is in slot 19. For ILCM unit 1, card is in slot 20.
To post the C-side PM, posted before in step 5, where the PRLCM is interfaced,
type:
>POST host_pm host_pm_no
and press the Enter key.
where
host_pm
is the name of the host PM (PLGC or RCO2)
host_pm_no
is the number of the host PM
Use the information collected in step 7. To busy both links for the defective
card, type :
>BSY LINK link_no
and press the Enter key.
where
link_no
is one of two links associated with the defective card.
Note: Repeat this step for the other link associated with the defective card.
WARNING
Calls in progress can be interrupted.
Wait at least 15 min to allow calls in progress to complete
before you remove the NT6X27 PCM-30 interface card.